Human Reproduction, Vol. 10, No. 3, pp. 620-625, 1995
© 1995 European Society of Human Reproduction and Embryology
research-article |
Andrology: External quality assessment for semen analysis and sperm antibody detection: results of a pilot scheme
Department of Reproductive Medicine, St Mary's Hospital Whitworth Park, Manchester M13 OJH, UK
Correspondence: 1Correspondence to be addressed at: Pivet Medical Centre, 166-168 Cambridge Street, Leederville 6008, Western Australia
The need for quality assurance in the seminology laboratory is clear, as the techniques of semen analysis and sperm antibody detection are just as susceptible to variation as any other routine pathology test. Semen samples were distributed to 20 laboratories on six occasions, four samples per distribution, for sperm concentration and morphology assessment under routine conditions, together with an equal number of serum samples for sperm antibody detection. The semen analysis results showed a wide range of values for any given sample, which did not seem to be related to the methodology used. However, this variation appears to be related to the presence of persistent errors, as most laboratories showed reasonable between-assay and within-assay variation. Detection of sperm antibodies by the tray agglutination, gelatin agglutination or indirect immuno-bead test showed a consistent discrimination between the intended positive and intended negative samples. However, the use of fluorescent microscopy was unable to do this. This study has shown the feasibility of operating external quality assessment schemes for semen analysis and sperm antibody detection. These schemes provide the opportunity for individual laboratories to fully evaluate their own methods against those of others and to determine the stages at which any errors occur. An increased number of participants will ultimately enable a systematic comparison of different methods.
Key words: quality assessment/semen analysis/sperm antibody detection
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
A.A. Pacey Is quality assurance in semen analysis still really necessary? A view from the andrology laboratory Hum. Reprod., May 1, 2006; 21(5): 1105 - 1109. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Riddell, A. Pacey, and K. Whittington Lack of compliance by UK andrology laboratories with World Health Organization recommendations for sperm morphology assessment Hum. Reprod., December 1, 2005; 20(12): 3441 - 3445. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Brazil, S. H. Swan, C. R. Tollner, C. Treece, E. Z. Drobnis, C. Wang, J. B. Redmon, and J. W. Overstreet Quality Control of Laboratory Methods for Semen Evaluation in a Multicenter Research Study J Androl, July 1, 2004; 25(4): 645 - 656. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Eustache and J. Auger Inter-individual variability in the morphological assessment of human sperm: effect of the level of experience and the use of standard methods Hum. Reprod., May 1, 2003; 18(5): 1018 - 1022. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Hancock and E McLaughlin British Andrology Society guidelines for the assessment of post vasectomy semen samples (2002) J. Clin. Pathol., November 1, 2002; 55(11): 812 - 816. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Bjorndahl, C.L.R. Barratt, L.R. Fraser, U. Kvist, and D. Mortimer ESHRE basic semen analysis courses 1995-1999: immediate beneficial effects of standardized training Hum. Reprod., May 1, 2002; 17(5): 1299 - 1305. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Auger, F. Eustache, A.G. Andersen, D.S. Irvine, N. Jorgensen, N.E. Skakkebak, J. Suominen, J. Toppari, M. Vierula, and P. Jouannet Sperm morphological defects related to environment, lifestyle and medical history of 1001 male partners of pregnant women from four European cities Hum. Reprod., December 1, 2001; 16(12): 2710 - 2717. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Auger, F. Eustache, B. Ducot, T. Blandin, M. Daudin, I. Diaz, S.E. Matribi, B. Gony, L. Keskes, M. Kolbezen, et al. Intra- and inter-individual variability in human sperm concentration, motility and vitality assessment during a workshop involving ten laboratories Hum. Reprod., November 1, 2000; 15(11): 2360 - 2368. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Martinez, C. Mar, M. Azcarate, P. Pascual, J.M. Aritzeta, and A. Lopez-Urrutia Sperm motility index: a quick screening parameter from sperm quality analyser-IIB to rule out oligo- and asthenozoospermia in male fertility study Hum. Reprod., August 1, 2000; 15(8): 1727 - 1733. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. A. Keel, P. Quinn, C. F. Schmidt Jr, N. T. Serafy Jr, N. T. Serafy Sr, and T. K. Schalue Results of the American Association of Bioanalysts national proficiency testing programme in andrology Hum. Reprod., March 1, 2000; 15(3): 680 - 686. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Bohring and W. Krause The intra- and inter-assay variation of the indirect mixed antiglobulin reaction test: is a quality control suitable? Hum. Reprod., July 1, 1999; 14(7): 1802 - 1805. [Abstract] [Full Text] [PDF] |
||||
![]() |
T.G. Cooper, A.D. Atkinson, and E. Nieschlag Experience with external quality control in spermatology Hum. Reprod., March 1, 1999; 14(3): 765 - 769. [Abstract] [Full Text] [PDF] |
||||