Skip Navigation

This Article
Right arrow FREE Full Text (PDF ) Freely available
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (67)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Lesny, P.
Right arrow Articles by Maguiness, S. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lesny, P.
Right arrow Articles by Maguiness, S. D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Human Reproduction, Vol 13, 1540-1546, Copyright © 1998 by Oxford University Press


ARTICLES

Embryo transfer--can we learn anything new from the observation of junctional zone contractions?

P Lesny, SR Killick, RL Tetlow, J Robinson and SD Maguiness
Academic Department of Obstetrics and Gynaecology, University of Hull, and Princess Royal Hospital, UK.

To assess whether embryo transfer can alter junctional zone contractility, we studied the effect of easy and difficult mock transfers in 14 oocyte donors during in-vitro fertilization (IVF) cycles. An Echovist bolus (30 microl) was used to represent embryos and transfer medium. An 'easy' transfer was judged to be an atraumatic insertion of the catheter without touching the uterine fundus. A 'difficult' embryo transfer was mimicked by deliberately touching the uterine fundus twice with the soft end of the cannula. Transvaginal scan images were recorded, digitized and converted into five times normal speed to allow us to evaluate junctional zone contractility. Easy mock embryo transfers did not change endometrial mechanical activity. Echovist remained in the upper part of the uterine cavity and was not dispersed after 45 min. A difficult procedure generated strong random waves in the fundal area and waves from fundus to cervix which relocated the Echovist in six out of seven cases. We observed movements of the transfer bolus from the upper part of the uterus towards the cervix (four cases) and into Fallopian tubes (two patients). Our study confirms that the mechanical activity of the uterus is capable of relocating intrauterine embryos and that this activity depends on physical stimulation. Junctional zone contractions can be implicated in cases of IVF/embryo transfer failure or ectopic gestation.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Hum ReprodHome page
R. T. Mansour, H. G. Al-Inany, A. M. Abou-Setta, L. Murad, G. I. Serour, and M. A. Aboulghar
Sperm suspension is a highly ultrasonically visible material: a novel model to study uterine activity
Hum. Reprod., July 1, 2007; 22(7): 1942 - 1945.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
A. M. Abou-Setta, H. G. Al-Inany, R. T. Mansour, G. I. Serour, and M. A. Aboulghar
Soft versus firm embryo transfer catheters for assisted reproduction: a systematic review and meta-analysis
Hum. Reprod., November 1, 2005; 20(11): 3114 - 3121.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
M. I. Shamonki, G. L. Schattman, S. D. Spandorfer, P. H. Chung, and Z. Rosenwaks
Ultrasound-guided trial transfer may be beneficial in preparation for an IVF cycle
Hum. Reprod., October 1, 2005; 20(10): 2844 - 2849.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
M. I. Shamonki, S. D. Spandorfer, and Z. Rosenwaks
Ultrasound-guided embryo transfer and the accuracy of trial embryo transfer
Hum. Reprod., March 1, 2005; 20(3): 709 - 716.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R. Matorras, R. Mendoza, A. Exposito, and F.J. Rodriguez-Escudero
Influence of the time interval between embryo catheter loading and discharging on the success of IVF
Hum. Reprod., September 1, 2004; 19(9): 2027 - 2030.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
J.G. Franco Jr, A.M.V.C. Martins, R.L.R. Baruffi, A.L. Mauri, C.G. Petersen, V. Felipe, P. Contart, A. Pontes, and J.B.A. Oliveira
Best site for embryo transfer: the upper or lower half of endometrial cavity?
Hum. Reprod., August 1, 2004; 19(8): 1785 - 1790.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
O. Eytan, D. Elad, U. Zaretsky, and A. J. Jaffa
A glance into the uterus during in vitro simulation of embryo transfer
Hum. Reprod., March 1, 2004; 19(3): 562 - 569.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
M.B. Henne and A.A. Milki
Uterine position at real embryo transfer compared with mock embryo transfer
Hum. Reprod., March 1, 2004; 19(3): 570 - 572.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
M.M.C. van de Pas, S. Weima, C.W.N. Looman, and F.J.M. Broekmans
The use of fixed distance embryo transfer after IVF/ICSI equalizes the success rates among physicians
Hum. Reprod., April 1, 2003; 18(4): 774 - 780.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
B. Coroleu, P. N. Barri, O. Carreras, F. Martinez, A. Veiga, and J. Balasch
The usefulness of ultrasound guidance in frozen-thawed embryo transfer: a prospective randomized clinical trial
Hum. Reprod., November 1, 2002; 17(11): 2885 - 2890.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
C. Tomas, K. Tikkinen, L. Tuomivaara, J. S. Tapanainen, and H. Martikainen
The degree of difficulty of embryo transfer is an independent factor for predicting pregnancy
Hum. Reprod., October 1, 2002; 17(10): 2632 - 2635.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R. Matorras, E. Urquijo, R. Mendoza, B. Corcostegui, A. Exposito, and F.J. Rodriguez-Escudero
Ultrasound-guided embryo transfer improves pregnancy rates and increases the frequency of easy transfers
Hum. Reprod., July 1, 2002; 17(7): 1762 - 1766.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R.T. Mansour and M.A. Aboulghar
Optimizing the embryo transfer technique
Hum. Reprod., May 1, 2002; 17(5): 1149 - 1153.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
F.P. Biervliet, P. Lesny, S.D. Maguiness, and S.R. Killick
Ultrasound-guided embryo transfer maximizes the IVF results on day 3 and day 4 embryo transfer but has no impact on day 5
Hum. Reprod., April 1, 2002; 17(4): 1131 - 1132.
[Full Text] [PDF]


Home page
Hum ReprodHome page
Y. Prapas, N. Prapas, A. Hatziparasidou, P. Vanderzwalmen, M. Nijs, S. Prapa, and G. Vlassis
Ultrasound-guided embryo transfer maximizes the IVF results on day 3 and day 4 embryo transfer but has no impact on day 5
Hum. Reprod., April 1, 2002; 17(4): 1132 - 1132.
[Full Text] [PDF]


Home page
Hum ReprodHome page
H. G.I. van Weering, R. Schats, J. McDonnell, J. M. Vink, J. P.W. Vermeiden, and P. G.A. Hompes
The impact of the embryo transfer catheter on the pregnancy rate in IVF
Hum. Reprod., March 1, 2002; 17(3): 666 - 670.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
P. Lesny, S. Maguiness, F. Biervliet, and S.R. Killick
Uterine contractility decreases at the time of blastocyst transfer
Hum. Reprod., March 1, 2002; 17(3): 841 - 841.
[Full Text] [PDF]


Home page
Hum ReprodHome page
F.P. Biervliet, P. Lesny, S.D. Maguiness, J. Robinson, and S.R. Killick
Transmyometrial embryo transfer and junctional zone contractions
Hum. Reprod., February 1, 2002; 17(2): 347 - 350.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
K. Kojima, M. Nomiyama, T. Kumamoto, Y. Matsumoto, and T. Iwasaka
Transvaginal ultrasound-guided embryo transfer improves pregnancy and implantation rates after IVF
Hum. Reprod., December 1, 2001; 16(12): 2578 - 2582.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
Y. Prapas, N. Prapas, A. Hatziparasidou, P. Vanderzwalmen, M. Nijs, S. Prapa, and G. Vlassis
Ultrasound-guided embryo transfer maximizes the IVF results on day 3 and day 4 embryo transfer but has no impact on day 5
Hum. Reprod., September 1, 2001; 16(9): 1904 - 1908.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
F. Martinez, B. Coroleu, M. Parriego, O. Carreras, I. Belil, N. Parera, L. Hereter, R. Buxaderas, and P.N. Barri
Ultrasound-guided embryo transfer: immediate withdrawal of the catheter versus a 30 second wait
Hum. Reprod., May 1, 2001; 16(5): 871 - 874.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
P.E. Egbase, M. Al-Sharhan, and J.G. Grudzinskas
Influence of position and length of uterus on implantation and clinical pregnancy rates in IVF and embryo transfer treatment cycles
Hum. Reprod., September 1, 2000; 15(9): 1943 - 1946.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
B. Coroleu, O. Carreras, A. Veiga, A. Martell, F. Martinez, I. Belil, L. Hereter, and P.N. Barri
Embryo transfer under ultrasound guidance improves pregnancy rates after in-vitro fertilization
Hum. Reprod., March 1, 2000; 15(3): 616 - 620.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
G. Kunz, D. Beil, P. Huppert, and G. Leyendecker
Structural abnormalities of the uterine wall in women with endometriosis and infertility visualized by vaginal sonography and magnetic resonance imaging
Hum. Reprod., January 1, 2000; 15(1): 76 - 82.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
E. G. Wood, F. R. Batzer, K. J. Go, J. N. Gutmann, and S. L. Corson
Ultrasound-guided soft catheter embryo transfers will improve pregnancy rates in in-vitro fertilization
Hum. Reprod., January 1, 2000; 15(1): 107 - 112.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
P. Lesny, S.R. Killick, J. Robinson, G. Raven, and S.D. Maguiness
Junctional zone contractions and embryo transfer: is it safe to use a tenaculum?
Hum. Reprod., September 1, 1999; 14(9): 2367 - 2370.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
G. I Meniru
Is Puregon a `good' or `super' drug?
Hum. Reprod., June 1, 1999; 14(6): 1409 - 1411.
[Full Text] [PDF]


Home page
Hum ReprodHome page
P. Lesny, S.R. Killick, R.L. Tetlow, D.J. Manton, J. Robinson, and S.D. Maguiness
Ultrasound evaluation of the uterine zonal anatomy during in-vitro fertilization and embryo transfer
Hum. Reprod., June 1, 1999; 14(6): 1593 - 1598.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.