Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF ) Freely available
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (21)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Jauniaux, E.
Right arrow Articles by Burton, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jauniaux, E.
Right arrow Articles by Burton, G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Human Reproduction, Vol. 14, No. 11, 2901-2904, November 1999
© 1999 European Society of Human Reproduction and Embryology

In-vivo measurement of intrauterine gases and acid–base values early in human pregnancy

Eric Jauniaux1,4, Adrian Watson3, Oskan Ozturk1, David Quick2 and Graham Burton3

1 Academic Departments of Obstetrics and Gynaecology, and 2 Anaesthetics, University College London (UCL), London and 3 Department of Anatomy, University of Cambridge, Cambridge, UK

A new multiparameter sensor that combines electrochemical and fibre-optic technology was used for continuous in-vivo investigation of pH, carbon dioxide partial pressure (PCO2), oxygen partial pressure (PO2), bicarbonate concentration (HCO3), base excess, and oxygen saturation (O2Sat) early in human pregnancy. The sensor was inserted into the amniotic cavity and the placental bed of 16 pregnancies at 10–15 weeks gestation, before termination under general anaesthesia. Amniotic fluid and retroplacental blood from the same site were also aspirated and analysed by means of cartridges and a portable blood gas analyser. Eleven series of measurements were obtained. The variation in measurements over the 5 min of monitoring was <=10% for all parameters. The sensor was damaged during insertion into the amniotic cavity in one case and in the placental bed in four cases. Measurements of PO2 in both the amniotic cavity and the placental bed and of pH in the placental bed were higher using the cartridges than in vivo. The results indicated that in-vivo monitoring of fetoplacental gas and acid–base with a sensor is stable and accurate. Such technology will be helpful in improving our understanding of the fetoplacental metabolism in normal and complicated pregnancies.

Key words: acid–base balance/gases/in-vivo measurements/placenta/pregnancy

4 To whom correspondence should be addressed at: The Academic Department of Obstetrics and Gynaecology, University College London Medical School, 86–96 Chenies Mews, LondonWC1E 6HX, UK


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Am. J. Pathol.Home page
E. Jauniaux, A. L. Watson, J. Hempstock, Y.-P. Bao, J. N. Skepper, and G. J. Burton
Onset of Maternal Arterial Blood Flow and Placental Oxidative Stress : A Possible Factor in Human Early Pregnancy Failure
Am. J. Pathol., December 1, 2000; 157(6): 2111 - 2122.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.