Skip Navigation


Hum. Reprod. Advance Access originally published online on July 2, 2009
Human Reproduction 2009 24(10):2490-2499; doi:10.1093/humrep/dep236
This Article
Right arrow Full Text
Right arrow Full Text (PDF )
Right arrow Supplementary Data
Right arrow All Versions of this Article:
24/10/2490    most recent
dep236v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Yamagata, K.
Right arrow Articles by Wakayama, T.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yamagata, K.
Right arrow Articles by Wakayama, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Assessment of chromosomal integrity using a novel live-cell imaging technique in mouse embryos produced by intracytoplasmic sperm injection

Kazuo Yamagata1, Rinako Suetsugu and Teruhiko Wakayama

Laboratory for Genomic Reprogramming, Center for Developmental Biology, RIKEN-Kobe, Minatojima-minamimachi 2-2-3, Chuo-ku, Kobe City, Hyogo 651-0047, Japan

1 Correspondence address. Tel: +81-78-306-3094; Fax: +81-78-306-3095; E-mail: yamagata{at}cdb.riken.jp

BACKGROUND: Intracytoplasmic sperm injection (ICSI) is a technique in which sperm are injected directly into unfertilized oocytes, whereby offspring can be obtained even with dysfunctional sperm. Despite its advantages in human and animal reproductive technology, the low rate of resultant live offspring is perturbing. One major cause is thought to be embryonic chromosomal abnormalities. However, there is no direct evidence of how these occur or how they affect pregnancy outcomes.

METHODS: Chromosomal dynamics during the first mitotic division of mouse embryos were analyzed using a new live-cell imaging technology. After imaging, the embryos' developmental capacities were determined.

RESULTS: When ICSI-generated embryos were monitored for their chromosome integrity, some embryos with apparent normal morphology seen by conventional light microscopy had abnormal chromosome segregation (ACS) at the first mitotic division. Chromosomal fragments were misaligned during the first metaphase and formed micronuclear-like structures at the interphase of the 2-cell stage. Similar ACS was also found in mouse embryos produced by microinjecting round spermatids, with even higher frequency. Giemsa staining and immunostaining revealed that these fragments were derived from double-strand DNA breaks in the paternal genome. About half of the embryos with ACS developed into normal-looking morulae or blastocysts and implanted, but almost all of them aborted spontaneously before embryonic day 7.5.

CONCLUSIONS: ACS during first mitosis appears to be a major cause of early pregnancy losses in ICSI-generated mouse embryos. Moreover, this novel imaging technology could be applicable as a method for the assessment of embryo quality.

Key words: intracytoplasmic sperm injection/abnormal chromosome segregation/early pregnancy loss/live-cell imaging/assisted reproductive technology

Submitted on January 19, 2009; resubmitted on June 2, 2009; accepted on June 4, 2009.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.