Skip Navigation

This Article
Right arrow Full Text (PDF )
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (34)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Mansour, R.T.
Right arrow Articles by Amin, Y.M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mansour, R.T.
Right arrow Articles by Amin, Y.M
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Human Reproduction, Vol. 9, No. 7, pp. 1257-1259, 1994
© 1994 European Society of Human Reproduction and Embryology


research-article

Infertility: Dummy embryo transfer using methylene blue dye

R.T. Mansour1, M.A. Aboulghar, G.I. Serour and Y.M Amin

The Egyptian IVF-Embryo Transfer Centre 85 Maadi Zeraei Road, Maadi, Cairo 11431, Egypt

Correspondence: 1To whom correspondence should be addressed

The aim of this prospective work was to evaluate different catheters and techniques used for embryo transfer. Studies were performed on 105 IVF patients before the start of treatment cycles. Each patient was used as her own control to study the expulsion of methylene blue (MB) dye after dummy embryo transfer. Group A (n = 35) underwent the test twice, before and after aspiration of the cervical mucus. Group B (n=30) underwent the test twice with and without the presence of two air bubbles in the embryo transfer catheter. Group C (n = 40) underwent the test twice using two different catheters, the Wallace and the Craft catheters. The results showed that the dye was extruded at the external os in 57% of the cases when the cervical mucus was not aspirated compared to 23% when the mucus was aspirated (P = 0.01). The dye was extruded in 33% of the cases with air bubbles in the catheter as compared to 27% when no air was present (P > 0.05). When the Wallace catheter was used expulsion occured in 25.5% compared to 77.5% when the Craft catheter was used. We concluded that using soft catheters and complete aspiration of cervical mucus significantly reduced the expulsion of the dye. The presence of air bubbles did not affect rate of expulsion of the dye.

Key words: embryo transfer/IVF/uterus


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Hum ReprodHome page
R. T. Mansour, H. G. Al-Inany, A. M. Abou-Setta, L. Murad, G. I. Serour, and M. A. Aboulghar
Sperm suspension is a highly ultrasonically visible material: a novel model to study uterine activity
Hum. Reprod., July 1, 2007; 22(7): 1942 - 1945.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R. Mansour
Minimizing embryo expulsion after embryo transfer: a randomized controlled study
Hum. Reprod., January 1, 2005; 20(1): 170 - 174.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
O. Eytan, D. Elad, U. Zaretsky, and A. J. Jaffa
A glance into the uterus during in vitro simulation of embryo transfer
Hum. Reprod., March 1, 2004; 19(3): 562 - 569.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R. Alvero, R.M. Hearns-Stokes, W.H. Catherino, M.P. Leondires, and J.H. Segars
The presence of blood in the transfer catheter negatively influences outcome at embryo transfer
Hum. Reprod., September 1, 2003; 18(9): 1848 - 1852.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
H.N. Sallam, A.F. Agameya, A.F. Rahman, F. Ezzeldin, and A.N. Sallam
Ultrasound measurement of the uterocervical angle before embryo transfer: a prospective controlled study
Hum. Reprod., July 1, 2002; 17(7): 1767 - 1772.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R.T. Mansour and M.A. Aboulghar
Optimizing the embryo transfer technique
Hum. Reprod., May 1, 2002; 17(5): 1149 - 1153.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
O. H. Salha, V. K. Lamb, and A. H. Balen
A postal survey of embryo transfer practice in the UK
Hum. Reprod., April 1, 2001; 16(4): 686 - 690.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
P.E. Egbase, M. Al-Sharhan, and J.G. Grudzinskas
Influence of position and length of uterus on implantation and clinical pregnancy rates in IVF and embryo transfer treatment cycles
Hum. Reprod., September 1, 2000; 15(9): 1943 - 1946.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
E. G. Wood, F. R. Batzer, K. J. Go, J. N. Gutmann, and S. L. Corson
Ultrasound-guided soft catheter embryo transfers will improve pregnancy rates in in-vitro fertilization
Hum. Reprod., January 1, 2000; 15(1): 107 - 112.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
P. Lesny, S.R. Killick, J. Robinson, G. Raven, and S.D. Maguiness
Junctional zone contractions and embryo transfer: is it safe to use a tenaculum?
Hum. Reprod., September 1, 1999; 14(9): 2367 - 2370.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.