Effect of using an echogenic catheter for ultrasound-guided embryo transfer in an IVF programme: a prospective, randomized, controlled study
1 Department of Obstetrics and Gynaecology, Service of Reproductive Medicine, Institut Universitari Dexeus 2 Institut Clinic of Gynaecology, Obstetrics and Neonatology, Faculty of Medicine-University of Barcelona, Hospital Clinic-Institut dInvestigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
3 To whom correspondence should be addressed at: Institut Universitari Dexeus. Paseo Bonanova 67, 08017 Barcelona, Spain. E-mail: vencor{at}dexeus.com
| Abstract |
|---|
|
|
|---|
BACKGROUND: Recent evidence showed that ultrasound-guided embryo transfer significantly increases successful implantation compared to the clinical touch method. It has been postulated that new echodense catheters which are more readily detectable by ultrasound may refine transfer techniques even more, thus improving IVF outcome. METHODS: A prospective, randomized, controlled trial comparing IVF outcome for women undergoing embryo transfer under ultrasound guidance by a single healthcare provider with random assignment according to a computer-generated randomization table to either standard soft Wallace catheter (standard catheter group, n = 95) or the new echogenic soft Wallace catheter (echogenic catheter group, n = 98). RESULTS: The use of the echodense catheter facilitated catheter identification under ultrasound, and thus the duration of the embryo transfer procedure since the loaded catheter was handed to the physician and up to embryo discharge was significantly shorter in the echogenic catheter group as compared with the standard catheter group. There were 39 and 53 clinical pregnancies in the standard catheter (41%) and echogenic catheter (54.1%) groups, respectively. This was not statistically significant (P = 0.08) according to the OR (0.6) and CIs (0.331.04). However, twin pregnancy rate was significantly increased (P < 0.01) with the use of the new catheter which was the underlying source for obtaining significant increase in implantation rate in this group (37.1%) as compared with the standard catheter group (23.2%). CONCLUSION: This pilot study suggests that the use of the echogenic Wallace catheter simplifies ultrasound-guided embryo transfer but not definite benefit in terms of pregnancy rates was obtained. In contrast, the use of the new catheter was associated with a significant increase in the number of twin pregnancies.
Key words: catheter system/embryo transfer/implantation rates/IVF/ultrasound guidance
| Introduction |
|---|
|
|
|---|
Over the past two decades, there have been increasing success rates with assisted reproductive technologies (ART). This improvement has been related mainly to improved stimulation protocols and embryology laboratory techniques. The method of embryo transfer, however, has remained very much the same, and when considered with other improvements in the clinic and laboratory, it is clear that this area has evolved poorly (Pasqualini and Quintans, 2002
Despite the fact that embryo transfer is the last decisive step on the way to a pregnancy in ART, traditionally embryo transfer has been viewed as an unimportant variable in the success of an ART treatment cycle. Only recent publications have stressed that, despite its apparent simplicity, the technique of embryo transfer is of utmost importance in maximizing the chances of pregnancy (Kovacs, 1999
; Salha et al., 2001
; Schoolcraft et al., 2001
; Mansour and Aboulghar, 2002
; Pasqualini and Quintans, 2002
; Sallam, 2005
).
There is now a general agreement in the IVF community that a smooth embryo transfer is critical for achieving high success rates, and both choice of technique and choice of embryo replacement catheter may play a crucial role in the uterine embryo replacement (Kovacs, 1999
; Salha et al., 2001
; Schoolcraft et al., 2001
; Mansour and Aboulghar, 2002
Pasqualini and Quintans, 2002
; Sallam, 2005
). Thus, two recent meta-analyses confirmed that ultrasound-guided embryo transfer significantly increases the clinical pregnancy and embryo implantation rates compared to the clinical touch method (Buckett, 2003
; Sallam and Sadek, 2003
). In addition, an even more recent systematic review and meta-analysis evaluating the firmness of the embryo transfer catheter as a single variable in relation to a successful transfer concluded that using soft embryo transfer catheters results in a significantly higher pregnancy rate as compared with firm catheters (Abou-Setta et al., 2005
).
Using the soft Wallace embryo transfer catheter system, we performed a randomized, controlled trial showing that implantation and pregnancy rates were improved with ultrasound-guided embryo transfer compared with clinical touch (Coroleu et al., 2000
). A recent development is the availability of the soft Wallace echogenic catheter (SureView Wallace Embryo Replacement Catheter; Smiths Medical, Hythe, Kent, UK), which utilizes new technology specifically designed to visually enhance the catheters appearance under ultrasound.
Therefore, this pilot study was designed to prospectively investigate the effect of using an echogenic catheter for ultrasound-guided embryo transfer in an IVF programme. The rationale for this study was that an echogenic embryo transfer catheter should be easier to see and make the transfer easier and quicker than the nonechogenic catheter. To this end, embryo transfer under transabdominal ultrasound guidance was performed by a single healthcare provider with random assignment to either standard or echogenic soft Wallace catheters.
| Materials and methods |
|---|
|
|
|---|
Patients and ovarian stimulation
Between September 2004 and January 2005, 188 patients from the IVF-embryo transfer programme of the Institut Universitari Dexeus Reproductive Medicine Service underwent ultrasound-guided fresh embryo transfers. They were aged between 25 and 43 years, and the main patient indications for IVF/ICSI included male factor, tubal infertility, unexplained infertility and endometriosis. Eligible patients who agreed to participate were randomized in two treatment groups: 92 patients underwent ultrasound-guided embryo transfer with the standard soft Wallace catheter (Smiths Medical) (standard catheter group) and 96 patients with the new soft SureViewTM Wallace catheter (echogenic catheter group). A flow chart of inclusion, randomization and dropout of patients treated in the study is shown in Figure 1.
|
The SureViewTM Wallace catheter combines all of the characteristics of the classic soft Wallace catheter, with the unique opportunity to view the entire length of the catheter under ultrasound. The echogenicity is brought about by small air bubbles contained within the polyurethane of the catheter lumen itself and used along the whole length of the catheter (Figure 2). Patients were randomized on the day of embryo transfer, prior to the procedure being carried out, according to a computer-generated randomization table. Sealed envelopes for the randomization list were used. The study was approved by the Ethics and Clinical Trials Committee of the Institut Universitary Dexeus, and all women involved gave informed consent to participate in the study.
|
As previously reported (Coroleu et al., 2000
In those patients having a previous poor response and/or basal (cycle days 24) FSH serum concentrations >10.5 IU/l which, according to our experience, is associated with poor responsive cycles (Barri et al., 2000
), we used a flare-up protocol. Leuprolide acetate (0.5 mg s.c. daily) was begun on day 2 of the menstrual cycle and continued until the day of HCG administration. Follicular stimulation with FSH plus HMG was initiated on day 3 of the menstrual cycle. On days 15 of ovarian stimulation, patients received 225 IU of recombinant FSH (Gonal-F; Serono S.A.) together with three ampoules of HMG (HMG Lepori; Farma-Lepori, Barcelona, Spain), followed from cycle day 6 onwards by an individual adjustment in the dosage based on daily serum estradiol levels and vaginal ultrasound follicle measurements.
The ovulatory injection of recombinant HCG (250 µg SC, Ovitrelle, Serono S.A.) was administered when a consistent rise in serum estradiol concentrations was associated with the presence of two or more follicles >18 mm in diameter. Oocyte aspiration was performed by vaginal ultrasonography 3537 h after HCG administration. IVF procedures, including ICSI, as well as the luteal phase support (additional doses of HCG or vaginal micronized progesterone according to ovarian response) used in our programme have been previously described in detail elsewhere (Calderón et al., 1995
; Martinez et al., 2000
).
Embryo transfer procedure
Two days after oocyte recovery, usually two (range one to three) embryos per patient were replaced depending upon the age of the patient, the indication for IVF, the number of previous IVF attempts and the number and quality of embryos available for replacement. Embryo quality was established according to the number and form of blastomeres and the percentage of cytoplasmic fragmentation as previously suggested (Plachot and Mandelbaum, 1990
). As previously reported (Coroleu et al., 2002a
,b), for statistical comparison purposes and to quantify objectively the embryo quality, those three variables were coded according to fixed criteria and then assigned an arbitrary score of 0, 2 or 4. Embryos having <4 blastomeres on day 2, or <6 blastomeres on day 3, after IVF, were scored 0. In contrast,
4- and
6-cell embryos on days 2 and 3, respectively, were scored 2. Irrespective of the day after IVF, symmetrical cells were scored 4, whereas asymmetrical ones scored 0. Embryos having <15%,
15 to <50% and
50% fragmentation were scored 4, 2 and 0, respectively, on both day 2 and day 3. Accordingly, an optimal quality embryo would score 10. For the final analysis of results, the embryo score per patient was considered as the mean value of the scores given to each of transferred embryos.
No mock or trial embryo transfer was performed, and the preparation for embryo transfer was the same for the two study groups (Coroleu et al., 2000
, 2002a
,b). Patients were placed in the lithotomy position, and the cervix was exposed using a bivalve especulum. The exocervix was cleaned with a phosphate-buffered saline (PBS) solution (Dulbeccos PBS solution; Irvine Scientific, Santa Anna, CA, USA), and the endocervical mucus was removed by means of a sterile Teflon catheter (Malleable Stylet Wallace, SIMCARE, Lancing, West Sussex, UK) connected to a syringe. Prior to embryo transfer, the endometrial thickness, the distance from the external cervical os to the fundal endometrial surface and the point of the tip of the catheter should reach for proper embryo replacement (approximately 15 mm from the fundal surface of the endometrium according to previous studies by us (Coroleu et al., 2002a
) was measured by means of transabdominal and transvesical (with full bladder) ultrasonography. To facilitate this measurement, the speculum was withdrawn, if necessary, so that the external cervical os could be seen. Transfer was performed by the same provider (B.C.) in all patients included in the present study.
The same transfer technique was scrupulously maintained with all patients. The Wallace embryo replacement catheters, either the standard or the SureViewTM, connected to an insulin syringe were used for embryo transfer. Both catheters possess a stiffer outer sheath that stabilizes the softer inner cannula which carries the embryos and actually enters the endometrial cavity for embryo transfer. The catheter was first loaded with transfer medium [50% synthetic serum substitute (Irvine Scientific) and IVF-50 medium (Scandinavian IVF Science, Göthenburg, Sweden), taking care to avoid air bubbles. The embryos were loaded in the catheter. Under ultrasound transabdominal guidance, the soft inner catheter was introduced into the cervix and passed through the internal cervical os without using the outer sheath whenever possible. If resistance was met, the inner sheath was withdrawn and the outer sheath of the catheter was then passed through the endocervix and placed to or just through the internal os, not advanced into the uterine cavity. Grasping the cervix with a tenaculum was performed to facilitate this manoeuvre only in difficult cases. The inner catheter was now threaded through the outer sheath and advanced under real-time ultrasound guidance to the preselected position. At this point, the distance between the catheter tip and the fundal endometrial surface was again measured using ultrasonography and was considered valid if it was found to be within 15 ± 2 mm from the uterine fundus. Otherwise, the inner catheter tip was very gently advanced or withdrawn and thus appropriately relocated, keeping its movement to an absolute minimum. This final distance between the catheter tip and the fundus was considered for analysis of the results. Ultrasound visualization of the catheter to obtain the preselected position for embryo transfer was assessed as excellent/good when the catheter could be easily tracked during the first pass with any or minimal transducer movement in the transverse plane. Fair/poor visualization during the procedure was recorded if marked transducer or catheter movements were necessary for appropriate catheter placement or suboptimal identification of the catheter was obtained.
In all transfers, only 30 µl of transfer medium, containing the embryos was gently expelled into the uterine cavity under sonographic control, which allowed the visualization of the transfer-associated air bubble (bubble of air between the embryos) into the uterine cavity. The catheter was gently removed immediately after transfer and then checked under a stereomicroscope to ensure that all embryos had been transferred. At the end of the procedure, patients remained resting in bed for 30 min. The ease of each transfer procedure was assessed according to the following criteria: very easy, when the catheter passed smoothly through the cervix; easy, when the rigid outer Teflon sheath was required; and difficult, when the use of a tenaculum was necessary in addition to the above.
For the specific purpose of this study, the embryologist recorded both the duration of embryo loading (i.e., the time elapsed since the embryos were removed from the incubator for loading until the loaded catheter was passed to the physician) and the duration of the embryo transfer procedure (defined as the time elapsed since the loaded catheter was handed to the physician till embryos were gently discharged into the uterus).
Pregnancy was diagnosed by increasing serum concentrations of
-HCG after embryo transfer, and the subsequent demonstration of at least one intrauterine gestational sac by ultrasonography at 6 weeks gestation or an ectopic pregnancy. Implantation rates were defined as the number of sacs seen on the 4-week postretrieval ultrasound per number of embryos transferred.
Hormone analyses and ultrasonography
Serum estradiol, FSH and
-HCG were determined by electrochemiluminiscence immunoassay (ECLIA) on the Elecsys 2010 analyser (Roche Diagnostics, Basel, Switzerland). The inter- and intra-assay coefficients of variation were 6.2 and 5.7% for estradiol, 5.3 and 1.8% for FSH and 5.1 and 4.5% for
-HCG, respectively. Ultrasonic scans for ovarian follicular measurements were performed using a Toshiba Power vision 6000 unit (Toshiba, Tokyo, Japan) equipped with a 57 MHz endovaginal probe (PVM-651VT). Transabdominal and transvesical (with full bladder) ultrasonograhy was carried out using a TOSBEE [SSA-240 A] convex 3.75 MHz (Toshiba).
Statistical analysis
Data are presented as mean ± SD and were analysed by Statistical Package for Social Sciences (SPSS, Chicago, IL, USA). We used the chi-square test and Fishers exact test to compare qualitative variables and Students t-test to compare quantitative variables. The significance level was set at P < 0.05. For pregnancy rate comparison between groups, the results are given in terms of odds ratio (OR) and 95% Cis, with OR > 1.0 corresponding to positive associations and OR < 1.0 corresponding to negative associations. CIs which did not include the value of 1.0 correspond to P-values < 0.05 and, hence, were considered statistically significant. Data were analysed according to intention-to-treat (ITT) population.
| Results |
|---|
|
|
|---|
The results are summarized in Tables I
|
|
|
|
Table II summarizes the data regarding ovarian response, ovum retrieval and IVF outcome in the two groups studied. The type of stimulation protocol, the duration of ovarian stimulation, the total amount of gonadotrophins administered, the number of follicles punctured, serum concentration of estradiol on the day of HCG injection, the number of oocytes retrieved, the number of embryos suitable for replacement and cryopreservation, the endometrial thickness on the day of embryo transfer, the number of embryos replaced, the proportion of patients with single embryo transfer and the quality of embryos replaced were similar for the two groups of ART patients. Remarkably, the numbers of embryos per replacement as well as the mean embryo score per replacement were almost identical in the two groups.
Characteristics of embryo transfer are presented in Table III. No significant differences were found when technical details of embryo transfer procedure including the mean catheter tiputerine fundus distance, the ease of transfer, the occurrence of blood-stained catheter and the number of patients with repeated transfer because of embryo(s) left at tip of catheter were compared, although the last three parameters were somewhat in favour of the echogenic catheter group. However, the ease of visualization of the catheter was significantly better in the echogenic catheter group. Also, while the duration of embryo loading was similar in both study groups, the duration of the embryo transfer procedure was significantly shorter in the echogenic catheter group as compared with the standard catheter group.
Clinical pregnancy rates per embryo transfer showed a 12.8% absolute difference (55.2 versus 42.4%) in favour of the echogenic catheter group, though this was not statistically significant (P = 0.08) according to the OR (0.6) and CIs (0.331.04). Implantation rate was significantly higher (P < 0.01) in the echogenic catheter group (37.1%) than in the standard catheter group (23.2%), but this did not translate into significant higher pregnancy rates. Thus, this fact implied that the number of twin pregnancies was significantly increased in the group where the new catheter was used (Table IV). The outcome of pregnancy was not different in the two groups studied (Table IV).
| Discussion |
|---|
|
|
|---|
Embryo transfer has emerged as a significant aspect influencing the success of IVF. Considerable attention is paid to atraumatic passage of the catheter through the uterine cavity and precise location of the catheter tip and site of transfer of the embryos. Easy and atraumatic transfers of embryos placed in the middle of the uterine cavity are considered essential for successful implantation (Levi Setti et al., 2003
Accordingly with the above postulates, two recent meta-analyses provided robust evidence in favour that ultrasound-guided embryo transfer using transabdominal ultrasound is significantly more effective than embryo transfer by clinical touch alone (Buckett, 2003
; Sallam and Sadek, 2003
). Catheters could be made more readily detectable by ultrasound to refine transfer techniques even more. Some catheters already in the market have this feature, due to an echodense tip [Cook Echo-Tip catheter (Cook Ob/Gyn, Spencer, IN, USA), a modification of the soft-tip Wallace catheter in that the catheter has an echogenic stainless steel band at the tip of the inner sheath) (Letterie et al., 1999
) or echogenicity extending along the whole length of the catheter (SureView Wallace embryo replacement catheter). It was hypothesized that these echogenic catheters could be immediately imaged by transabdominal ultrasonography, and with small movements of the transducer in the transverse plane, the echodense catheter would be easily tracked during passage through the entire uterine cavity into the fundal region during the first pass. This would minimize the to-and-fro motion necessary to identify the catheter tip which, in turn, would minimize disruption of the endometrium with improvement in implantation rates (Letterie et al., 1999
).
The above notwithstanding, a prospective, randomized study concluded that the use of the Cook Echo-Tip catheter simplifies ultrasound-guided embryo transfer and the need to move the catheter for identification, but no differences in success rates were observed when compared with the standard Wallace catheter (Karande et al., 2002
). In the current investigation, pregnancy rates were similar in the two study groups, but the upper limit of the 95% CI (1.04) and the P-value (0.08) obtained when the OR was used for comparison purposes between groups suggest that a trend in favour of the new echogenic catheter may exist. However, twin pregnancy rate was significantly increased (P < 0.01) with the use of the new catheter which was the underlying source for a significant increase in implantation rate in this group (37.1%) as compared with the standard catheter group (23.2%). In this respect, it is to note that twins and higher multiple births tend to be disadvantageous from the start, and reducing the multiple gestation pregnancy rate is considered to be a high priority for ART programmes (The ESHRE Capri Workshop Group, 2000
). Therefore, the current study is still early work, and further data are needed to determine the real magnitude of any benefit with echogenic catheters, and if possible which patients would benefit the most.
The exact mechanism whereby ultrasound-guided embryo transfer improves clinical pregnancy rates and embryo implantation is unclear, although confirming the position of the tip of the embryo transfer catheter actually within the uterine cavity obviously is a major benefit (Woolcott and Stanger, 1997
; Buckett, 2003
). A number of studies have suggested other mechanisms whereby the IVF outcome is improved with ultrasound-guided embryo transfer, by increasing the frequency of easy transfers (Matorras et al., 2002
), by avoiding bloody and/or repeated transfers (Sallam et al., 2002
; Alvero et al., 2003
) or by properly replacing the embryos in the midcavity (Coroleu et al., 2002a
). In the current study, those physical aspects of embryo transfer as well as the depth of embryo replacement into the uterine cavity were similar in both study groups (Table III). No mock or trial embryo transfer was performed in the current investigation, but a recent study (Henne and Milki, 2004
) reported the lack of consistency in the uterine position between mock and real embryo transfer and stressed the value of using transabdominal ultrasound guidance in order to more accurately assess the uterine position and to avoid misdirecting the embryo transfer catheter.
Remarkably, however, a recent study showed that the time interval from loading the embryo transfer catheter to depositing the embryos in the uterine cavity is a prognostic factor of the implantation and pregnancy rates independent of transfer difficulty (Matorras et al., 2004
). It was postulated that a longer interval loading-discharging embryos would favour the influence of some environmental factors potentially having detrimental effects on oocytes and embryos such as exposure to light, temperature, inappropriate O2 and CO2 concentrations and other environmental conditions which would decrease implantation rates (Matorras et al., 2004
). These authors stressed, however, that a relatively prolonged endocervical manipulation could also play a role (Matorras et al., 2004
). In fact, limiting the time of embryo manipulation during the transfer technique may increase pregnancy rates after ART (Tomás et al., 2002
; Neithardt et al., 2005
). This is supported by the current study where the duration of the embryo transfer procedure from the moment when the loaded catheter was handed to the physician and up to embryo discharge was significantly shorter in the echogenic catheter group (having a higher implantation rate) than in the standard catheter group. The shorter duration of the embryo transfer procedure among patients in the echogenic catheter group would be explained by the use of the echodense catheter which facilitated catheter identification under ultrasound. This is to be noted considering that, as in our previous studies (Coroleu et al., 2002a
,b
), all embryo transfers were performed by a single experienced physician who consistently used the same technique, thus avoiding any impact of the physician factor on implantation rates (Karande et al., 1999
; Hearns-Stokes et al., 2000
).
In conclusion, our results suggest that the use of the echogenic SureView catheter simplifies ultrasound-guided embryo transfer as compared with the widely used standard soft Wallace catheter. This notwithstanding, although this study provided sound data for later interpretation, it was intended to be a pilot study and was therefore limited by a lack of power. With a sample size of 95 and 98 patients for the standard catheter and the echogenic catheter groups, respectively, and an
of 0.05, our study had a power of 44% to detect a 13.1% absolute difference (41.0 versus 54.1%) in clinical pregnancy rate per randomized patient. Three hundred and six subjects in each catheter group would be needed to conclude that a true difference between groups existed if the reported pregnancy rates were true. Therefore, further studies are needed to confirm our results.
| Acknowledgements |
|---|
|
|
|---|
This work was performed under the auspices of Catedra dInvestigació en Obstetricia I Ginecología of Department of Obstetrics and Gynaecology, Institut Universitari Dexeus, Universitat Autònoma de Barcelona. We are indebted to N. Rodríguez for statistical analysis of the data.
| References |
|---|
|
|
|---|
Abou-Setta AM, Al-Inany HG, Mansour R, Serour GI, Aboulghar MA. (2005) Soft versus firm embryo transfer catheters for assisted reproduction: a systematic review and meta-analysis. Hum Reprod 20:31143121 [Advance Access published July 29, 2005].
Alvero R, Hearns-Stokes RM, Catherino WH, Leondires MP, Segars JH. (2003) The presence of blood in the transfer catheter negatively influences outcome at embryo transfer. Hum Reprod 18:18481852.
Barri PN, Coroleu B, Martinez F, Veiga A. (2000) Stimulation protocols for poor responders and aged women. Mol Cell Endocrinol 166:1520.[CrossRef][Web of Science][Medline]
Buckett WM. (2003) A meta-analysis of ultrasound-guided versus clinical touch embryo transfer. Fertil Steril 80:10371041.[CrossRef][Web of Science][Medline]
Calderón G, Belil L, Arán B, Veiga A, Gil Y, Boada M, Martinez F, Parera N, Coroleu B, Penella J, et al. (1995) Intracytoplasmic sperm injection versus conventional in-vitro fertilization: first results. Hum Reprod 10:28352839.
Coroleu B, Carreras O, Veiga A, Martell A, Martinez F, Belil I, Hereter L, Barri PN. (2000) Embryo transfer under ultrasound guidance improves pregnancy rates after in-vitro fertilization. Hum Reprod 15:616620.
Coroleu B, Barri PN, Carreras O, Martinez F, Parriego M, Hereter L, Parera N, Veiga A, Balasch J. (2002a) The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: a controlled, ultrasound-guided study. Hum Reprod 17:341346.
Coroleu B, Barri PN, Carreras O, Martinez F, Veiga A, Balasch J. (2002b) The usefulness of ultrasound guidance in frozenthawed embryo transfer: a prospective randomized clinical trial. Hum Reprod 17:28852890.
The ESHRE Capri Workshop Group. (2000) Multiple gestation pregnancy. Hum Reprod 15:18561864.
Eytan O, Elad D, Zaretsky U, Jaffa AJ. (2004) A glance into the uterus during in vitro stimulation of embryo transfer. Hum Reprod 19:562569.
Hearns-Stokes RM, Miller BT, Scott L, Creuss D, Chakraborty PK, Segars JH. (2000) Pregnancy rates after embryo transfer depend on the provided at embryo transfer. Fertil Steril 74:8086.[CrossRef][Web of Science][Medline]
Henne MB and Milki AA. (2004) Uterine position at real embryo transfer compared with mock embryo transfer. Hum Reprod 19:570572.
Karande V, Morris R, Chapman C, Rinehart J, Gleicher N. (1999) Impact of the "physician factor" on pregnancy rates in a large assisted reproductive technology program: do too many cooks spoil the broth? Fertil Steril 71:10011009.[CrossRef][Web of Science][Medline]
Karande V, Hazlett D, Vietzke M, Gleicher N. (2002) A prospective randomized comparison of the Wallace catheter and the Cook Echo-Tip catheter for ultrasound-guided embryo transfer. Fertil Steril 77:826830.[CrossRef][Web of Science][Medline]
Kovacs GT. (1999) What factors are important for successful embryo transfer after in-vitro fertilization? Hum Reprod 14:590592.
Letterie GS, Marshall L, Angle M. (1999) A new coaxial catheter system with an echodense tip for ultrasonographically guided embryo transfer. Fertil Steril 72:266268.[CrossRef][Web of Science][Medline]
Levi Setti PE, Albani E, Cavagna M, Bulletti C, Colombo GV, Negri L. (2003) The impact of embryo transfer on implantation a review. Placenta 24:S20MS26.
Mansour RT and Aboulghar MA. (2002) Optimizing the embryo transfer technique. Hum Reprod 17:11491153.
Martinez F, Coroleu B, Parera N, Alvarez M, Traver JM, Boada M, Barri PN. (2000) Human chorionic gonadotropin and intravaginal natural progesterone are equally effective for luteal phase support in IVF. Gynecol Endocrinol 14:316320.[Web of Science][Medline]
Matorras R, Urquijo E, Mendoza R, Corcóstegui B, Expósito A, Rodriguez-Escudero FJ. (2002) Ultrasound-guided embryo transfer improves pregnancy rates and increases the frequency of easy transfers. Hum Reprod 17:17621766.
Matorras R, Mendoza R, Expósito A, Rodriguez-Escudero FJ. (2004) Influence of the time interval between embryo catheter loading and discharging on the success of IVF. Hum Reprod 19:20272030.
Neithardt AB, Segars JH, Hennessy S, James AN, McKeeby JL. (2005) Embryo afterloading: a refinement in embryo transfer technique that may increase clinical pregnancy. Fertil Steril 83:710714.[Medline]
Pasqualini RS and Quintans S. (2002) Clinical practice of embryo transfer. Reprod Biomed Online 4:8392.[Medline]
Plachot M and Mandelbaum J. (1990) Oocyte maturation, fertilization and embryonic growth in vitro. Br Med Bull 46:675694.
Salha OH, Lamb VK, Balen AH. (2001) A postal survey of embryo transfer practice in the UK. Hum Reprod 16:686690.
Sallam HN. (2005) Embryo transfer: factors involved in optimizing the success. Curr Opin Obstet Gynecol 17:289298.[Web of Science][Medline]
Sallam HN and Sadek SS. (2003) Ultrasound-guided embryo transfer: a meta-analysis of randomized controlled trials. Fertil Steril 80:10421046.[CrossRef][Web of Science][Medline]
Sallam HN, Agameya AF, Rahman AF, Ezzeldin F, Sallam AN. (2002) Ultrasound measurement of the uterocervical angle before embryo transfer: a prospective controlled study. Hum Reprod 17:17671772.
Schoolcraft WB, Surrey ES, Gardner DK. (2001) Embryo transfer: techniques and variables affecting success. Fertil Steril 76:863870.[CrossRef][Web of Science][Medline]
Tomás C, Tikkinen K, Tuomivaara L, Tapanainen J, Martikainen H. (2002) The degree of difficulty of embryo transfer is an independent factor for predicting pregnancy. Hum Reprod 17:26322635.
Woolcott R and Stanger J. (1997) Potentially important variables identified by transvaginal ultrasound-guided embryo transfer. Hum Reprod 12:963966.
Submitted on November 10, 2005; resubmitted on December 28, 2005; accepted on January 27, 2006.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
Z. Yao, S. Vansteelandt, J. Van der Elst, T. Coetsier, M. Dhont, and P. De Sutter The efficacy of the embryo transfer catheter in IVF and ICSI is operator-dependent: a randomized clinical trial Hum. Reprod., April 1, 2009; 24(4): 880 - 887. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||