Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF ) Freely available
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (16)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Yaman, C.
Right arrow Articles by Tews, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yaman, C.
Right arrow Articles by Tews, G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Human Reproduction, Vol. 14, No. 10, 2604-2608, October 1999
© 1999 European Society of Human Reproduction and Embryology

Reproducibility of transvaginal three-dimensional endometrial volume measurements during ovarian stimulation

C. Yaman1,3, M. Sommergruber1, T. Ebner1, W. Pölz2, M. Moser1 and G. Tews1

1 Women's General Hospital, Department of Assisted Reproduction, Lederergasse 47, A-4020 Linz 2 University of Linz, Department for Statistics, Altenbergerstr. 69, A-4040 Linz, Austria

Before estimating the clinical role of a method, the reproducibility has to be evaluated precisely. This study aimed to document the reproducibility of the endometrial volume measurement by three-dimensional (3D)-ultrasound. The volume measurements were done on 57 consecutive in-vitro fertilization (IVF) patients with either the full planar (contour) or the three distance method. A paired t-test provided no statistically significant difference between the two methods. Linear regression analysis, using the full planar method as independent and the other as dependent variables, yielded the following results: intercept = 0.348, not statistically different from 0; slope = 0.962, statistically different from 1 (P < 0.01). Interobserver reliability for the three distance method was 0.6667 and for the full planar method was 0.9565. Intra-observer reliability for the three distance method was 0.8426 and for the full planar method 0.9394. The correspondence between and within observers seemed to be good. Both methods are reliable, but the full planar method seems to provide slightly better reproducibility in regard to endometrium volume measurement.

Key words: endometrium volume/IVF/reproducibility/three-dimensional ultrasound

3 To whom correspondence should be addressed


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Hum ReprodHome page
T. J. Child, C. Sylvestre, and S. L. Tan
Endometrial volume and thickness measurements predict pituitary suppression and non-suppression during IVF
Hum. Reprod., December 1, 2002; 17(12): 3110 - 3113.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
C. Yaman, T. Ebner, M. Sommergruber, J. Hartl, W. Polz, and G. Tews
Three-dimensional endometrial volume estimation as a predictor of pituitary down-regulation in an IVF-embryo transfer programme
Hum. Reprod., August 1, 2000; 15(8): 1698 - 1702.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.