Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF ) Freely available
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (73)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Coroleu, B.
Right arrow Articles by Barri, P.N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Coroleu, B.
Right arrow Articles by Barri, P.N.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Human Reproduction, Vol. 15, No. 3, 616-620, March 2000
© 2000 European Society of Human Reproduction and Embryology

Embryo transfer under ultrasound guidance improves pregnancy rates after in-vitro fertilization

B. Coroleu1, O. Carreras, A. Veiga, A. Martell, F. Martinez, I. Belil, L. Hereter and P.N. Barri

Service of Reproductive Medicine, Department of Obstetrics and Gynaecology, Institut Universitari Dexeus, Pso. Bonanova 67, 08017 Barcelona, Spain

Between October 1998 and January 1999, we examined the influence of ultrasound guidance in embryo transfer on pregnancy rate in 362 patients from our in-vitro fertilization (IVF)–embryo transfer programme. These patients were prospectively randomized into two groups: 182 had ultrasound-guided embryo replacement, and 180 had clinical touch embryo transfer. There were no statistically significant differences between the two groups with respect to age, cause of infertility and in the characteristics of the IVF cycle. The pregnancy rate was significantly higher among the ultrasound-guided embryo transfer group (50%) compared with the clinical touch group (33.7%) (P < 0.002). Furthermore, there was also a significant increase in the implantation rate: 25.3% in the ultrasound group compared with 18.1% in the clinical touch group (P < 0.05). In conclusion, ultrasound assistance in embryo transfer significantly improved pregnancy and implantation rates in IVF.

Key words: clinical touch/implantation rate/IVF/pregnancy rate/ultrasound-guided embryo transfer

1 To whom correspondence should be addressed


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Hum ReprodHome page
A. J. Drakeley, A. Jorgensen, J. Sklavounos, T. Aust, R. Gazvani, P. Williamson, and C. R. Kingsland
A randomized controlled clinical trial of 2295 ultrasound-guided embryo transfers
Hum. Reprod., May 1, 2008; 23(5): 1101 - 1106.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
F. Martinez, M. Boada, B. Coroleu, E. Clua, N. Parera, I. Rodriguez, and P.N. Barri
A prospective trial comparing oocyte donor ovarian response and recipient pregnancy rates between suppression with gonadotrophin-releasing hormone agonist (GnRHa) alone and dual suppression with a contraceptive vaginal ring and GnRH
Hum. Reprod., August 1, 2006; 21(8): 2121 - 2125.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
B. Coroleu, P. N. Barri, O. Carreras, I. Belil, R. Buxaderas, A. Veiga, and J. Balasch
Effect of using an echogenic catheter for ultrasound-guided embryo transfer in an IVF programme: a prospective, randomized, controlled study
Hum. Reprod., July 1, 2006; 21(7): 1809 - 1815.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
M. I. Shamonki, G. L. Schattman, S. D. Spandorfer, P. H. Chung, and Z. Rosenwaks
Ultrasound-guided trial transfer may be beneficial in preparation for an IVF cycle
Hum. Reprod., October 1, 2005; 20(10): 2844 - 2849.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
M. I. Shamonki, S. D. Spandorfer, and Z. Rosenwaks
Ultrasound-guided embryo transfer and the accuracy of trial embryo transfer
Hum. Reprod., March 1, 2005; 20(3): 709 - 716.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
A.R. Thornhill, C.E. deDie-Smulders, J.P. Geraedts, J.C. Harper, G.L. Harton, S.A. Lavery, C. Moutou, M.D. Robinson, A.G. Schmutzler, P.N. Scriven, et al.
ESHRE PGD Consortium 'Best practice guidelines for clinical preimplantation genetic diagnosis (PGD) and preimplantation genetic screening (PGS)'
Hum. Reprod., January 1, 2005; 20(1): 35 - 48.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
M.B. Henne and A.A. Milki
Uterine position at real embryo transfer compared with mock embryo transfer
Hum. Reprod., March 1, 2004; 19(3): 570 - 572.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
P. Serhal, D. M. Ranieri, I. Khadum, and R. A. Wakim
Cervical dilatation with hygroscopic rods prior to ovarian stimulation facilitates embryo transfer
Hum. Reprod., December 1, 2003; 18(12): 2618 - 2620.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R. Alvero, R.M. Hearns-Stokes, W.H. Catherino, M.P. Leondires, and J.H. Segars
The presence of blood in the transfer catheter negatively influences outcome at embryo transfer
Hum. Reprod., September 1, 2003; 18(9): 1848 - 1852.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
M.M.C. van de Pas, S. Weima, C.W.N. Looman, and F.J.M. Broekmans
The use of fixed distance embryo transfer after IVF/ICSI equalizes the success rates among physicians
Hum. Reprod., April 1, 2003; 18(4): 774 - 780.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
E. V. Mocanu
The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: a controlled, ultrasound-guided study
Hum. Reprod., April 1, 2003; 18(4): 889 - 889.
[Full Text] [PDF]


Home page
Hum ReprodHome page
B. Coroleu
The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: a controlled, ultrasound-guided study
Hum. Reprod., April 1, 2003; 18(4): 889 - 890.
[Full Text] [PDF]


Home page
Hum ReprodHome page
B. Coroleu, P. N. Barri, O. Carreras, F. Martinez, A. Veiga, and J. Balasch
The usefulness of ultrasound guidance in frozen-thawed embryo transfer: a prospective randomized clinical trial
Hum. Reprod., November 1, 2002; 17(11): 2885 - 2890.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R. Matorras, E. Urquijo, R. Mendoza, B. Corcostegui, A. Exposito, and F.J. Rodriguez-Escudero
Ultrasound-guided embryo transfer improves pregnancy rates and increases the frequency of easy transfers
Hum. Reprod., July 1, 2002; 17(7): 1762 - 1766.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
H.N. Sallam, A.F. Agameya, A.F. Rahman, F. Ezzeldin, and A.N. Sallam
Ultrasound measurement of the uterocervical angle before embryo transfer: a prospective controlled study
Hum. Reprod., July 1, 2002; 17(7): 1767 - 1772.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R.T. Mansour and M.A. Aboulghar
Optimizing the embryo transfer technique
Hum. Reprod., May 1, 2002; 17(5): 1149 - 1153.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
F. Martinez, P.N. Barri, B. Coroleu, R. Tur, T. Sorsa-Leslie, W. J. Harris, N. P. Groome, P. G. Knight, and P. A. Fowler
Women with poor response to IVF have lowered circulating gonadotrophin surge-attenuating factor (GnSAF) bioactivity during spontaneous and stimulated cycles
Hum. Reprod., March 1, 2002; 17(3): 634 - 640.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
H. G.I. van Weering, R. Schats, J. McDonnell, J. M. Vink, J. P.W. Vermeiden, and P. G.A. Hompes
The impact of the embryo transfer catheter on the pregnancy rate in IVF
Hum. Reprod., March 1, 2002; 17(3): 666 - 670.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
B. Coroleu, P. N. Barri, O. Carreras, F. Martinez, M. Parriego, L. Hereter, N. Parera, A. Veiga, and J. Balasch
The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: a controlled, ultrasound-guided study
Hum. Reprod., February 1, 2002; 17(2): 341 - 346.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
K. Kojima, M. Nomiyama, T. Kumamoto, Y. Matsumoto, and T. Iwasaka
Transvaginal ultrasound-guided embryo transfer improves pregnancy and implantation rates after IVF
Hum. Reprod., December 1, 2001; 16(12): 2578 - 2582.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
O. S. Tang, E. H. Y. Ng, W. W. K. So, and P. C. Ho
Ultrasound-guided embryo transfer: a prospective randomized controlled trial
Hum. Reprod., November 1, 2001; 16(11): 2310 - 2315.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
Y. Prapas, N. Prapas, A. Hatziparasidou, P. Vanderzwalmen, M. Nijs, S. Prapa, and G. Vlassis
Ultrasound-guided embryo transfer maximizes the IVF results on day 3 and day 4 embryo transfer but has no impact on day 5
Hum. Reprod., September 1, 2001; 16(9): 1904 - 1908.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
F. Martinez, B. Coroleu, M. Parriego, O. Carreras, I. Belil, N. Parera, L. Hereter, R. Buxaderas, and P.N. Barri
Ultrasound-guided embryo transfer: immediate withdrawal of the catheter versus a 30 second wait
Hum. Reprod., May 1, 2001; 16(5): 871 - 874.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
O. H. Salha, V. K. Lamb, and A. H. Balen
A postal survey of embryo transfer practice in the UK
Hum. Reprod., April 1, 2001; 16(4): 686 - 690.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
M. A. Pascual, J. Ruiz, F. Tresserra, C. Sanuy, P. J. Grases, R. Tur, and P. N. Barri
Cervical ectopic twin pregnancy: diagnosis and conservative treatment: Case report
Hum. Reprod., March 1, 2001; 16(3): 584 - 586.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
R. J.P. Rijnders, B. W.J. Mol, F. J. Broekmans, and B. Coroleu
Use of ultrasound guidance during embryo transfer
Hum. Reprod., November 1, 2000; 15(11): 2449 - 2449.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.