Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF ) Freely available
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (8)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Rosenlund, B.
Right arrow Articles by Hovatta, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rosenlund, B.
Right arrow Articles by Hovatta, O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Human Reproduction, Vol. 16, No. 10, 2154-2159, October 2001
© 2001 European Society of Human Reproduction and Embryology

Percutaneous cutting needle biopsies for histopathological assessment and sperm retrieval in men with azoospermia

Björn Rosenlund1,4, Ulrik Kvist2, Leif Plöen2,3, Urban Ekström2 and Outi Hovatta1

1 Department of Obstetrics and Gynaecology, Huddinge University Hospital, Andrology Centre, Department of Woman and Child Health, 2 Karolinska Hospital, Stockholm and 3 Department of Anatomy and Histology, Swedish University of Agricultural Sciences, Uppsala, Sweden

BACKGROUND: Twenty-three men (45 testes) with azoospermia underwent percutaneous testicular biopsy under local anaesthesia. METHODS: In all but one of the 45 testes two biopsies were taken close to each other, one with a 16 gauge (n = 44) and another with a 14 gauge (n = 45) cutting needle, both with a 19 mm notch. Three quarters of the tissue was used for histopathological assessment and one quarter for direct microscopy. RESULTS: The histopathological findings were similar between the two needles. The observations with direct microscopy corresponded with the histopathological assessments concerning the presence of mature spermatids in 41 of 45 (91%) biopsies using the 14 gauge and in 40 of 44 (91%) biopsies using the 16 gauge needle. There were no post-operative complications except for minimal pain and minor local swelling. CONCLUSIONS: Percutaneous material retrieved using 16 gauge and 14 gauge needles is sufficient for histopathological assessment, and the two needles are equally reliable for testicular sperm retrieval. However, needle biopsy with one puncture may not be representative of the entire testis.

Key words: azoospermia/histopathological diagnosis/percutaneous needle biopsy/spermatogenesis

4 To whom correspondence should be addressed. E-mail: bjorn.rosenlund{at}obgyn.hs.sll.se


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Hum ReprodHome page
L. M. Rossi, L. A.V. Pereira, L. de Santis, F. F. Pasqualotto, A. Iaconelli Jr, V. Ortiz, and E. Borges Jr
Sperm retrieval techniques in rats with suppressed spermatogenesis by experimental cryptorchidism
Hum. Reprod., February 1, 2005; 20(2): 443 - 447.
[Abstract] [Full Text] [PDF]


Home page
J AndrolHome page
J. S. Moldenhauer, G. C. Ostermeier, A. Johnson, M. P. Diamond, and S. A. Krawetz
Diagnosing Male Factor Infertility Using Microarrays
J Androl, November 1, 2003; 24(6): 783 - 789.
[Full Text] [PDF]


Home page
J AndrolHome page
S. Wood, E. Vang, J. Manning, J. Walton, S. Troup, C. Kingsland, and I. D. Lewis-Jones
The Ratio of Second to Fourth Digit Length in Azoospermic Males Undergoing Surgical Sperm Retrieval: Predictive Value for Sperm Retrieval and on Subsequent Fertilization and Pregnancy Rates in IVF/ICSI Cycles
J Androl, November 1, 2003; 24(6): 871 - 877.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.